  • alarme 02 da fujitsu invert

    bom dia estou com um problema com uma maquina da fujitsu 18.000 BTU invert com o alarme 02 piscando não entra o evaporador, como posso resetar esse alarme. obrigado. This article is also published as a forum topic here »

  • ar condicionado springer 10.000 btus

    /* Style Definitions */ table.MsoNormalTable {mso-style-name:”Tabela normal”; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-priority:99; mso-style-qformat:yes; mso-style-parent:””; mso-padding-alt:0cm 5.4pt 0cm 5.4pt; mso-para-margin-top:0cm; mso-para-margin-right:0cm; mso-para-margin-bottom:10.0pt; mso-para-margin-left:0cm; line-height:115%; mso-pagination:widow-orphan; font-size:11.0pt; font-family:”Calibri”,”sans-serif”; mso-ascii-font-family:Calibri; mso-ascii-theme-font:minor-latin; mso-fareast-font-family:”Times New Roman”; mso-fareast-theme-font:minor-fareast; mso-hansi-font-family:Calibri; mso-hansi-theme-font:minor-latin;} O meu ar condicionado springer 10.000 btus, liga por alguns minutos e depois desarma, não chegando a gelar o ambiente, peço ajuda…

3 Comentários

  1. Olha nos manuais de instalação que já vem com a equação de perdas. Algumas máquinas já vem com carga para até 3 metros de distância, evaporadora /condensadora e outras para até 5 metros, mas geralmente acrescentamos 30 gr por metro adicionado ou desnível + joelhos.

    Sendo que na maioria das máquinas quando o desnível entre evaporadora (acima) condensadora (abaixo) for mais que três metros são necessários a colocação de sifões para evitar o golpe de liquido no compressor.

  2. Boa tarde,companheiro o critério é simples coloque o manometro na linha de baixa e através da leitura que deverá ficar em 67 psi voce saberá se é necessário ou não. independente da distancia a pressão e sempre a mesma.